Date: April 30,2003 Test Executive Version: 7.01 Agilent ESG_C Test Package Version: B.07.01 Welcome to the Agilent Service Support Software with the Agilent ESG E4438C Test package! PLEASE READ THESE NOTES BEFORE RUNNING THE APPLICATION! These notes are designed to help you understand characteristics of this application and to inform you of any last minute changes. OVERVIEW This is the Revision B.07.01 of test software for the Agilent ESG E4438C RF Signal Generator series (ESG C family). This software includes a Test Executive (User Interface) and a package of Adjustments/Performance Tests that apply specifically to the Agilent ESG E4438C series. This software should be used in conjunction with the Agilent ESG E4438C Calibration Guide. MODELS AND OPTIONS COVERED The following models and options are covered by this software: MODEL # OPTIONS E4438C 1E5 1E6 001 002 300 400 401 UN7 UNB UNJ 501 502 503 504 506 GENERAL Please be sure to install and configure the SICL I/O libraries that came with your GP-IB card before running the application. Only Agilent Technologies GP-IB interface cards are supported at this time. The first time the application is run, the system administrator needs to enter information about the test equipment available at your site for this application. This is done through the File, Test Equipment menu items. If this is not done, the software will not allow testing. NOTE: If you are using any power sensors, each must have a default GPIB address of -1. If you get an error while running the application, first check for obvious problems such as equipment not connected, cables not attached, equipment not turned on, etc. Note any information the error message gives you which may be useful to HP customer support should you need their help. Always try to duplicate the error condition, and as a last resort, try rebooting your PC if the application hangs up. TECHNICAL SUPPORT For assistance, please FAX your questions to Agilent ESG Support at (1) (707) 577-6011. Please include a complete description of your request along with the following information: Your name Company Address Telephone number (plus extension) FAX number e-mail address Your message will be responded to promptly. PERFORMANCE TESTS -- Power Level Accuracy--: Power level measurements made at low power levels are very susceptable to errors caused by RF leakage into the measurement system. It is extremely important that the Device Under Test as well as all test equipment be isolated from stray RF signals as much as possible during these measurements. ADJUSTMENTS -- I/Q Impairment--: This adjustment requires the RF Output is properly terminated. Connect either a 10 dB attenuator or power sensor to the DUT RF Output for this adjustment. POWER METER SUBSTITUTION The E4419B power meter used in this software only uses the A Input. Therefore, an E4418B can be substituted without the need to change any software drivers. -- I/Q Time Skew - Baseband and RF--: These adjustments require firmware revision C.03.10 or higher. REVISION HISTORY: o ESG E4438C Test Package: Revision B.07.00 (Original release) o ESG E4438C Test Package: Revision B.07.01 (I/Q Time Skew Cal) Added two adjustments for I/Q Time Skew Cal: The tests calibrate the I/Q time skew (phase difference between the I and Q channels) on the BB or RF I/Q Outputs for various setup condtions. The data is then stored in the instrument calibration arrays for time skew. The tests use an 8563E to make the required measurements of the DUT I/Q baseband or RF Outputs. Note: These adjustments require firmware revision C.03.10 or higher. Fixed the following defects: 1. Harmonics performance test (phar): Fixed datapack for 3 GHz model. Tried to check signal at too high a frequency. 2. Subharmonics(pshar): Fixed datapack for 3 GHz model. Incorrectly numbered datapoints. 3. Power Level Accuracy performance test (pla_vsa): Fixed problem with Step Attenuator Driver software driver. It was incorrectly setting pads for some 70 dB step attenuator models. This could also affect ESG B and ESG AP/DP software.